The Standard in Rugged Power Products

Home Up Products Representation Employment News Resources Search Feedback

ETI0001-2221 2.2 kVA All of these products are manufactured by ETI in the United States.

Up
ETI0001-1202 1.5 kVA
ETI0001-1214 3.0 kVA
ETI0001-1229 2.0 kVA
ETI0001-1230 1.5 kVA
ETI0001-1230AA 1.5 kVA
ETI0001-1233 2.0 kVA
ETI0001-1233AA 2.0 kVA
ETI0001-1235 1.0 kVA
ETI0001-1237 2.0 kVA
ETI0001-1237AA 2.0 kVA
ETI0001-1240 1.0 kVA
ETI0001-1241 3.0 kVA
ETI0001-1242 1.0 kVA
ETI0001-1250 1.5 kVA
ETI0001-1251 1.5 kVA
ETI0001-1251AE 1.5 kVA
ETI0001-1252 1.5 kVA
ETI0001-1253 2.0 kVA
ETI0001-1254 2.0 kVA
ETI0001-1255 1.5 kVA
ETI0001-1285AA 1.5 kVA
ETI0001-1287AA 1.0 kVA
ETI0001-2205A3 5.0 kVA
ETI0001-2205E1 3.0 kVA
ETI0001-2205E2 3.0 kVA
ETI0001-2210 1.5 kVA
ETI0001-2214 3.0 kVA
ETI0001-2215 4.0 kVA
ETI0001-2221 2.2 kVA
ETI0001-2227 1.0 kVA
ETI0001-2227AA 1.0 kVA
ETI0001-2227AB 1.0 kVA
ETI0001-2227AC 1.0 kVA
ETI0001-2227AD 1.0 kVA
ETI0001-2227AG 1.0 kVA
ETI0001-2227E 1.0 kVA
ETI0001-2228 1.5 kVA
ETI0001-2228AA 1.5 kVA
ETI0001-2228AC 1.5 kVA
ETI0001-2228E 1.5 kVA
ETI0001-2229 2.0 kVA
ETI0001-2229AG 2.0 kVA
ETI0001-2229AM 2.0 kVA
ETI0001-2229E 2.0 kVA
ETI0001-2250 2.0 kVA
ETI0001-2250AB 2.0 kVA
ETI0001-2258 1.5 kVA
ETI0001-2275 2.0 kVA
ETI0015-2221 1.1 kVA
ETI0015-2222 2.0 kVA

Part Number: ETI0001-2221
NSN: 6130-01-537-3889
Rugged Mil Spec® Rack or Fixed Mount
2200 VA UPS
Both AC and DC Outputs
Hot Swappable Batteries

US Navy AN/WDL-1 Mine Sweeper Standard Product
2.2 kVA Mil Spec UPS w/ AC and DC Outputs
Rugged Rack or Fixed Mount Unit 
w/ Reduced Depth and Removable Battery Modules

ETI0001-2221 Rugged MilSpec UPS Standard Front Panel Layout


ETI0001-2221 Rugged Mil Spec UPS Standard Front Panel Layout

NSN: 6130-01-537-3889

ETI0001-2221 Rugged MilSpec UPS Standard Rear Panel Layout
ETI0001-2221 Rugged Mil Spec UPS Standard Rear Panel Layout

The field proven Military Power® UPS line is ideally suited for military, industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The "ETI0001-2221" is being used by the US Navy on the WLD-1 project because of their stringent performance and reliability requirements. 

The heavy-duty chassis, occupying only 10.5" (6U) of rack space and 19" depth, has rounded metal corners and rugged handles front and rear, aiding in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. 

The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The unit also operates as a frequency converter, taking 46-440 hertz input and converting it to clean, uninterruptible 60 hertz power. The input switch and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent. 

The LED arrays keep the operator informed as to the unit's status including load and battery levels. The high intensity audible alarm can be heard in high noise environments. All controls and protective devices are brought to the front and rear panels with critical switches having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely. 

The rear panel provides barrier terminal blocks for the input and output power. Multiple input and output power panel options are available. Removable and washable air filters and a high capacity stainless steel ball bearing fans provide added protection in both controlled and hostile environments. The exhaust air is diverted out the rear vent, with alternate air flow directions optional. The "ETI0001-2221" has the added benefit of having field replaceable batteries via a front drawout battery modules. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials. For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability. 

See the Power Distribution Units section for a listing of stand alone PDUs. See the N5 Series ETI0001-1482 for a version of this UPS with an integrated PDU and remote control.

Overall, the Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

Technical Specifications:
P/N: ETI0001-2221

NSN: 6130-01-537-3889

OUTPUTS
Output voltage: 
    UPS AC:
    UPS DC:


120 VAC true sinewave standard
28 VDC
isolated
28 VDC isolated
28 VDC isolated
Output rating: 
    UPS Total:
    DC Outputs:

 

2200 VA total including DC outputs, up to 1500 VA AC
5 amps @ 28 VDC
11 amps @ 28 VDC
15 amps @ 28 VDC respectively
Non-linear load capacity: UPS Up to 100% non-linear load capability w/o derating
Output voltage regulation: UPS ± 3.0% static regulation of nominal
± 4.0% dynamic (0 to 50% load step)
Overload surge capacity: UPS 110% for 10 minutes; 125% for 30 seconds
Harmonic distortion: UPS Less than 5.0% into 100% non-linear load
Output frequency: UPS 60 Hz ± 1.0% independent of input frequency
50, 400 or 1000 Hz output available as an option
Operational status Status, load and battery LEDs, w/contacts
Adjustable level,+90 dB audible alarm w/on/off
AC INPUT
Input voltage selection: Nominal 115 VAC, optional autoranging input of 85-270 VAC
Input voltage tolerance: UPS 85-135 VAC @ full load without using battery, to 70 VAC @ 75% load
Input frequency: From 46 Hz to 440 Hz standard
Input power factor: Better than 99% typically
Input/output isolation: 2200 VA, up to 120 dB common mode, <1.0 mA leakage
Input transient suppression: Complies with IEEE 587 and UL 1449
Input control/protection: Guarded 2 pole toggle circuit breaker
Input power connection: Barrier terminal block
INTERNAL BATTERY
Internal battery type: Maintenance free immobilized electrolyte,
Flame retardant materials (Oxygen Index 28+)
Internal battery life: Rated for continuous service life of 5 years
Internal DC protection: Front panel mounted fuse standard, breaker optional
Internal battery time: 30+ minutes @ 100% load, 60+ minutes @ 50%
Internal battery recharge: Recharged to nominal in <8 hours
Internal battery replacement: (2) Drawout/plug-in modules from front of unit
DISTRIBUTION PANEL
Output circuits: Four outputs standard, optional configurations
Output control: Guarded toggle circuit breakers
Output receptacles: Barrier terminal blocks
MECHANICAL
Dimensions ( H x D x W ): 10.5 (6U) x 19.1 x 19.0 in (267 x 485 x 483 mm)
Rack Slide Mount Patterns: Jonathan, General Devices patterns, others optional
Alternate Mounting Options: Table, Wall, Floor, Portable, Horizontal/Vertical
Unit weight:
  UPS w/o Battery
  Internal Battery Module

95 lb. (43 kg) UPS with lift handles front and rear
64 lb. (29 kg) Each Battery Module
Audible noise: Less than 47 dB @ 5.0 ft., ANSI "A" scale
Cooling type: High capacity, positive pressure, forced air
Cooling air direction: Front intake, exhaust to rear, others optional
Air intake filter: Washable metal filter media, others optional
ENVIRONMENTAL
Storage temperature: -40° to 158° F ambient (-40° to 70° C) with fully charged batteries
Operating temperature: -4° to 131° F ambient ( -20° to 55° C), lower/ higher optional
Operating humidity: 0 to 95% relative humidity (non-condensing)
Storage elevation: Up to 40,000 ft (12,192 m)
Operating elevation: Up to 15,000 ft (4,572 m), higher optional
STANDARDS
United States: Meets UL-1778 standard for UPS equipment,
MIL STDs 167-1, 454, 810, 901D Grade A, 1399-300A & 2000
Canada: CSA C22.2 No. 107 UPS safety requirements
EMI Protection: EMI/RFI FCC Part 15, Class A; EN55022; MIL STD 461 
OPTIONAL ACCESSORIES
Autoranging International Input, Cold Start, Emergency Power Off, Elapsed Time Meter, Alternate I/O Configurations, Dual Source Input, Battery Expansion, Batteryless Operation, Battery Charger/Conditioner, Power Distribution Units, Software Interface,  Asynchronous serial COM port, 10BaseT Ethernet SNMP/HTTP port, Transport Cases, Slides and Mounting Kits

This page was last modified on: April 12, 2012
The N5 is one of the most popular configurations for new programs!

  Request Information

ETI Rugged Power UPS are the proven Standard!

Home Up Products Representation Employment News Resources Search Feedback

Send questions or comments about this web site to sales@ruggedsystems.com.
Copyright © 1991-2012 Energy Technologies, Inc. All Rights Reserved. Last modified: April 10, 2012
1st Energy™, 1st Power™, 911 Power™, AC anytime™, AC anywhere™, AC backup™, Airborne UPS™, Air Force Backup™, Air Force UPS™, Army UPS™, Backup AC™, Backup Source™, Backup The Web™, Battle Power™, Blackout Prevention™, Business Back UPS™, clean UPS™, Coast Guard Power™, Coast Guard UPS™, Controlling Power™, DC backup™, Disaster Recovery Gear™, Eco Power Source™, eDocs Port™, Energy Tech™, ETI™, Expeditionary Solar™, Extreme Power Source™, Global Power Source™, Global UPS™, Homeland Security Surveillance™, Humanitarian Power™, Hybrid Energy Storage™, Improved Power™, Industrial Backup™, Intelligent PDU™,  Intelligent UPS™, Internet Power Manager™, Lab Power™, Lab UPS™, Light UPS™, Know Power™, Marine Corps Power™, Marine UPS™, Medical Grade Power™, Military Backup™, Navy Power™, Navy UPS™, Network Power Manager™, Office UPS™, open UPS™, Personal Power Source™, Petro Chem Power™, Pipeline Power™, Portable Power Plant™, Powering The Net™, Power Protection™, Power Security™, Preventing Blackouts™, Radar Power™, Railroad Power™, Redundant Power™, Renewable Source™,  Rugged Power™, Rugged Systems™, Rugged UPS™, SCADA power™, Security Gate Power™, Shipboard Power™, Shipboard UPS™, Signal Backup™, Solar Backup™, Solar Power Source™, Soldier Power™, Tactical Computers™, Tactical Medical Office™, Tactical Office™, Tactical Solar Fly™, Tactical Trailer™, Tactical Water Plant™, Telecom Power Source™, the Warfighter™, Traffic Backup™, Traffic Signal Backup™, UPStart™, Utility Backup™, and Warfighter Power™  are trademarks of Energy Technologies, Inc.

Airborne Power®, Diplomatic Power®, Expeditionary Power®, Extreme UPS®, Hybrid Energy Technologies®, Industrial Power Source®, Military Power®,  Mil Spec®, Personal Solar®, Tactical Cables®, Tactical Cooling®, Tactical Computer Workstation®, Tactical Data Vault®, Tactical Field Office®, Tactical Fuel Cells®, Tactical Generator®, Tactical Inverter®, Tactical Micro Grid®, Tactical Power®, Tactical Power Plant®, Tactical Shelter Systems®, Tactical Solar®, Tactical Solar Shelter®, Tactical UPS®, Tactical Vehicle Power®, Tactical Wind Turbine® and Ultimate Survival Gear® are registered trademarks of Energy Technologies, Inc.

Legal Statements